1995 Ford F150 Fuel Pump Fuse: Your Essential Location, Testing, and Replacement Guide
The fuse for the fuel pump in your 1995 Ford F150 is a vital component located in the cab's fuse panel. Specifically, look for the fuse labeled "Fuel Pump" (or "FP") or identified as Fuse #17 (a 20 Amp fuse) on the fuse panel diagram located on the inside of the fuse panel cover. This fuse protects the electrical circuit powering your fuel pump. If it blows, your fuel pump won't function, preventing your engine from starting or running. Understanding its exact location, how to test it, and replace it correctly is essential knowledge for any 1995 F150 owner or mechanic.
Locating the Fuse Panels in Your 1995 Ford F150
Your truck has two primary fuse panels:
- Power Distribution Center (PDC): This is the large black box under the hood. It houses higher-amperage fuses and relays, typically mounted near the battery or firewall.
- Passenger Compartment Fuse Panel: This panel is critical for accessories and interior functions. It's located low down on the driver's side dashboard, to the left of the steering column near the hood release lever. To access it, you pull off its plastic cover. Crucially, the fuel pump fuse (#17) is located inside this passenger compartment panel.
Finding the Exact Fuel Pump Fuse: #17
- Access the Panel: Locate the cover on the driver's side lower dashboard. Pull firmly to remove it.
- Locate the Diagram: The cover should have a molded plastic or printed label diagram showing the fuse positions and amperages.
- Identify Fuse #17: Find the listing for "Fuel Pump," "FP," or simply the number "17" on this diagram. If the diagram is missing or unreadable, physically count the slots. Fuses are typically numbered sequentially, often starting at the top-left or top-right. Count positions carefully. Fuse #17 will be a standard blade-type fuse.
- Confirm the Amperage: The diagram will specify the fuse rating. For the 1995 F150 fuel pump circuit, it must be a 20 Amp (20A) fuse. Visually inspect the fuse itself; the amperage rating (20A) is usually printed on its top plastic housing.
Why the Fuel Pump Fuse Matters
The fuel pump fuse acts as a safety device. If an electrical fault occurs in the fuel pump circuit – like a short to ground, a failing pump drawing excessive current, or occasionally during intense vibration events – the fuse intentionally blows (melts a thin wire inside). This cuts power to the fuel pump to prevent:
- Electrical Fire: Overheating wires and components pose a significant fire hazard.
- Circuit Damage: High current flow can destroy wiring, switches, relays, or the fuel pump itself.
- Control Module Failure: Faults can sometimes send damaging currents back to vital engine computers.
Symptoms of a Blown 1995 F150 Fuel Pump Fuse
The primary symptom is no fuel delivery.
- Engine Cranks but Won't Start: This is the most obvious sign. The engine turns over normally when you turn the key, but it never actually fires up. You won't hear the fuel pump priming for 1-2 seconds when you first turn the ignition to the "Run" position (before cranking).
- Engine Stalls Suddenly While Driving: If the fuse blows while the engine is running, it will cause immediate stalling. The engine will crank normally afterward but won't restart.
- No Noise From the Fuel Tank: When you turn the key to "Run" (without cranking), you should hear a distinct humming or buzzing sound for 1-2 seconds from the rear of the truck. No sound often points to no power, potentially from a blown fuse.
- Check Engine Light may or may not illuminate. A blown fuse itself doesn't usually set a diagnostic trouble code (DTC) directly related to the fuse. Codes might set for secondary issues like low fuel pressure.
Accurately Testing the Fuel Pump Fuse (The Right Way)
- Safety First: Turn the ignition OFF. Remove the key. Consider disconnecting the negative battery terminal for added safety, though it's not always mandatory just for fuse testing.
- Access the Fuse: Remove the passenger compartment fuse panel cover as described.
- Visual Inspection: Carefully look at the small window on top of the plastic fuse housing for Fuse #17. If the thin metal wire inside is broken or the plastic looks discolored or "sooty," the fuse is blown.
-
Use a Fuse Tester (Recommended): A simple automotive fuse tester (available at any auto parts store) is the easiest and safest tool. Clip the tester's ground lead to a clean, unpainted metal surface inside the cab (like a bolt). Touch the tester's probe tip to the small metal tabs exposed on the TOP of the fuse.
- Test one side: Light illuminates = Good circuit to this point. Light out = Problem exists between battery and this fuse.
- Test the other side: Light illuminates = Good circuit from this point to ground. Light out = Fuse is blown.
- Multimeter Test (Continuity): Set a digital multimeter to the continuity setting (often indicated by a speaker or diode symbol). Remove the fuse from its slot. Touch one probe to each metal prong (blade) of the fuse. If the fuse is good, the meter will beep or display a reading near 0 Ohms. If blown, it will show infinite resistance or no continuity (no beep). This method requires fuse removal.
- Multimeter Test (Voltage - Caution): Turn ignition to "Run" (do not crank). Set multimeter to DC Voltage (20V range). Touch the black probe to a known good ground. Carefully touch the red probe to each small metal tab exposed on the TOP of the fuse while it's plugged in. You should measure battery voltage (approx. 12V) on one tab. Voltage present on one side but not the other usually indicates a blown fuse. Be extremely careful probing live circuits.
How to Replace a Blown Fuel Pump Fuse Correctly
- Buy the Correct Replacement: Purchase a pack of 20 Amp standard automotive blade fuses (ATC or ATO style). Use the exact amperage rating specified (20A). NEVER use a fuse with a higher rating (like 25A or 30A) – this defeats the safety function and risks fire. Using a lower rating means the fuse may blow prematurely.
- Safety First (Again): Turn off the ignition and remove the key. For major electrical work, disconnecting the negative battery terminal is wise. When replacing just one fuse, extreme caution while handling is usually sufficient.
- Remove the Old Fuse: Using a fuse puller tool (often provided in the fuse panel lid or a small plastic tool near it) or carefully with needle-nose pliers, grip the blown fuse by its plastic body and pull it straight out of its slot. Avoid pulling by the metal blades.
- Insert the New Fuse: Orient the new 20A fuse correctly – the blades fit only one way. Push it firmly but gently straight down into the slot labeled #17 or "Fuel Pump" until it seats fully.
- Verify: Reinstall the fuse panel cover. Turn the ignition to "Run" (without cranking). You should now hear the fuel pump prime for 1-2 seconds (a humming/buzzing sound from the rear). If the prime sound is present, attempt to start the engine. If it starts and runs normally, the immediate problem is fixed.
Important: What to Do AFTER Replacing a Blown Fuse
- Test Drive Carefully: Pay close attention to how the truck runs. Note any hesitation, misfires, or unusual sounds, especially from the fuel tank area.
- Monitor: If the fuse blows again immediately upon turning the key, or shortly after starting/driving, STOP. You have a serious underlying electrical fault or a failing fuel pump that needs diagnosis.
-
Diagnose the Root Cause: A blown fuse is rarely random on an older truck like a 1995 F150. Common causes include:
- Aging/Failing Fuel Pump: As fuel pumps wear out, they draw excessive current, overloading the fuse.
- Wiring Harness Damage: Chafed, pinched, or corroded wires in the circuit leading to the fuel pump (especially near the tank, frame rails, or where wires pass through metal).
- Faulty Fuel Pump Relay: While less common than a fuse issue, a sticking relay can sometimes cause problems. The relay for the fuel pump in a 1995 F150 is typically located under the hood in the Power Distribution Center.
- Shorts to Ground: Anywhere in the fuel pump circuit (power wire to frame/body).
- Poor Connections: Corrosion at fuse terminals, relay sockets, or pump connector.
- Seek Professional Help for Persistent Issues: If the fuse blows again, diagnosing the underlying electrical fault requires expertise and tools like wiring diagrams, test lights, multimeters, and potentially isolating sections of the circuit. Incorrect diagnosis can be dangerous. A qualified mechanic should trace the short circuit or verify the fuel pump's condition. Ignoring recurring blown fuses risks vehicle damage or fire.
Differentiating Between a Blown Fuse and a Dead Fuel Pump
Both conditions often share symptoms: no start, no pump priming sound. Here’s how to tell them apart:
- Check the Fuse First: It's the easiest and cheapest thing to rule out. Follow the testing procedures above.
-
Listen for Prime: If you don't hear the prime sound and the fuse is good, the problem could be:
- A faulty fuel pump relay (located in the under-hood PDC).
- A bad inertial safety switch (an impact cutoff device, usually located in the passenger footwell kick panel or behind the glove box - refer to owner's manual for exact 1995 location).
- Wiring problems between the fuse panel/relay/inertia switch and the pump.
- The pump itself is dead.
- Fuel Pressure Test: The definitive way to diagnose a pump. A mechanic or experienced DIYer can attach a gauge to the Schrader valve (like a tire valve) on the fuel injection rail. If pressure doesn't rise when the key is turned to "Run," and you've confirmed power/ground at the pump and checked the relay/inertia switch, the pump is likely faulty. Lack of power at the pump connector points back to fuse, relay, inertia switch, or wiring.
Preventative Measures and Pro Tips
- Carry Spare Fuses: Keep extra 20A fuses (and other common amperages like 10A, 15A, 30A) in your glove box or center console. Spares are inexpensive and essential.
- Know the Fuse Panel: Study your fuse panel diagram beforehand. Knowing layout in daylight helps immensely when troubleshooting in the dark or rain.
- Avoid Modifications: Do not splice into the fuel pump circuit or add accessories that draw power from it unless you fully understand the electrical load and fuse requirements.
- Address Rattles/Noises: Strange noises from the fuel tank area (whining, grinding) indicate impending pump failure. Replace it before it strands you and potentially blows the fuse upon failure.
- Be Wary of Water: While the cab panel is somewhat protected, heavy water intrusion (like deep floods) can cause fuse panel corrosion leading to intermittent issues or shorts. Ensure door seals and cowl panels are intact.
- Use Quality Parts: When replacing the fuel pump itself, use a reputable brand. Cheap pumps often fail prematurely and can have higher failure rates causing electrical issues.
Conclusion
A blown fuel pump fuse (#17, 20 Amp) is a common culprit behind a suddenly non-starting 1995 Ford F150. Knowing precisely where to find this fuse in the passenger compartment panel beneath the dashboard on the driver's side, and how to test and replace it with the correct amperage (20A) replacement, is fundamental troubleshooting knowledge. Always inspect and test the fuse if your engine cranks but won't start and the fuel pump doesn't prime when you turn the key. Remember that a blown fuse is usually a symptom pointing to another problem within the fuel system's electrical circuit – such as a failing fuel pump or damaged wiring. Replacing the fuse is simple and gets you moving again temporarily, but diagnosing and repairing the underlying fault causing the fuse to blow is essential for reliable long-term operation and safety. Keep spare fuses handy and address any recurring electrical issues promptly.